Electrochemical Carbon Monoxide Gas Sensor (CO Sensor) - 7E & 7E/F CiTiceL
• Operating Principle: 3-electrode electrochemical
• Measurement Range: 0-1000 ppm CO
• Maximum Overload: 2000 ppm CO
• Sensitivity: 0.10 ± 0.02 µA/ppm
• Repeatability: 1% of signal
• Linearity: Linear
• Operating Temperature Range: -20°C to +50°C
• Operating Humidity Range: 15 - 90% RH non-condensing
- Quantity:
- - +
Product Specification
7E & 7E/F CiTiceL Carbon Monoxide Sensor (CO Sensor) Key Features & Benefits:
• Robust, industry standard 7-Series packaging
• Compact Size
7E & 7E/F CiTiceL Carbon Monoxide Sensor (CO Sensor) Technical Specifications
MEASUREMENT | |
Operating Principle | 3-electrode electrochemical |
Measurement Range | 0-1000 ppm CO |
Maximum Overload | 2000 ppm CO |
Filter: | |
7E | None |
7E/F | To remove SOx/NOx and H 2 S |
Sensitivity | 0.10 ± 0.02 µA/ppm |
Response Time (T 90 ): | |
7E | <25 Seconds at 20°C |
7E/F | <30 Seconds at 20°C |
Baseline Offset (clean air) | -1 to +3 ppm equivalent |
Zero Shift (-20°C to +40°C) | <9 ppm equivalent |
Repeatability | 1% of signal |
Linearity | Linear |
ELECTRICAL | |
Recommended Load Resistor | 10 Ω |
Bias Voltage | Not Required |
MECHANICAL | |
Weight | 17 g |
Housing Material: | |
Cap | Polycarbonate |
Body | ABS |
Orientation | Any |
ENVIRONMENTAL | |
Typical Applications | Portable Life Safety |
Operating Temperature Range | -20°C to +50°C |
Recommended Storage Temp | 0°C to 20°C |
Operating Pressure Range | Atmospheric ± 10% |
Pressure Coefficient | 0.020 ± 0.008 % signal/mBar |
Operating Humidity Range | 15 - 90% RH non-condensing |
LIFETIME | |
Long Term Sensitivity Drift | <5% signal loss/year |
Expected Operating Life | Three years in air |
Storage Life | 6 months in CTL container |
Standard Warranty | 24 months from date of despatch |
* Specifications are valid at 20°C, 50% RH and 1013 mBar, using City Technology recommended circuitry. Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time.
Poisoning
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
If you cannot find what you want, you can entrust ISweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)