All-in-one Solution for Optical Oxygen Measurement - Portavo 907 Multi Oxy
- High-resolution color graphic display
- Transflective and sunlight readable
- Li-ion battery
- Optical oxygen sensor
- Integrated pressure measurement for compensating air pressure fluctuations
- Micro USB port and Paraly SW 112 software
- Quantity:
- - +
Product Specification
Portavo 907 Multi Oxy
The all-in-one solution for optical oxygen measurement. Multiparameter device for digital pH, conductivity and oxygen sensors with Memosens technology
The only portable device for all Memosens parameters. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition.
The data logger for up to 10,000 entries records measuring point, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp and device status.
User-friendly software
Portavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context- sensitive help.
Portavo 907 Multi Oxy Optical Oxygen Measurement Facts
- High-resolution color graphic display
- Transflective and sunlight readable
- Li-ion battery
- Optical oxygen sensor
- Integrated pressure measurement for compensating air pressure fluctuations
- Micro USB port and Paraly SW 112 software
- A sensor quiver protects the sensor from damage and drying out
- The high-performance polymer housing ensures low water absorption and high impact resistance
- Intelligent data logger with 10,000 entries and graphical representation
- IP 66/67 protection
- The mineral glass display is perfectly readable even after years
Comprehensive data logger
The following logging types can be selected:
- Manual logging
- Time-controlled logging at a fixed interval
- Signal-controlled logging of measured value and temperature
- Combined time- and signal-controlled logging
- Threshold-controlled logging with pre-trigger
Portavo 907 Multi Oxy Optical Oxygen Measurement Specifications
Optical oxygen input
|
M12 socket for SE 340 sensor or Memosens sensors | ||
OXY meas. ranges at 20 °C
|
Saturation | 0.000 ... 200.0 % | |
Concentration | 000 μg/l … 20.00 mg/l | ||
Partial pressure | 0.0 … 1000 mbars | ||
Response time
|
t90 < 30 s | ||
t99 < 60 s | |||
Measurement error | Zero signal < 0.1 % full saturation | ||
Measuring cycle | Approx. 1 s | ||
Measurement error | < 0.1 % meas. val. | ||
Temperature meas. range | 0.0 … 50.0 °C | ||
Measurement error | Temperature ± 0.2 K | ||
Sensor standardization
|
Automatic calibration in air, humidity adjustable | ||
Zero calibration | |||
Max. overpressure | 2.5 bars | ||
Immersion depth
|
min. 60 mm | ||
max. 25 m | |||
Storage Temperature input
|
Quiver | ||
2 x 4 mm dia. for integrated or separate temperature detector | |||
Measuring ranges
|
NTC 30 kΩ | -20 … +120 °C | |
Pt 1000 | -40 … +250 °C | ||
Measuring cycle | Approx. 1 s |
|
|
Measurement error1,2,3) < 0.2 K (Tamb = 23 °C) | TC < 25 ppm/K | ||
Memosens pH input (also ISFET)
|
M8 socket, 4 pins, for Memosens lab cable and M12 socket, 8 pins | ||
Display ranges
|
pH | -2.000 … +16.000 | |
mV | -2000 … +2000 mV | ||
Temperature | -50 … +250 °C | ||
Memosens ORP input
|
M8 socket, 4 pins, for Memosens lab cable and M12 socket, 8 pins | ||
Display ranges
|
mV | -2000 … +2000 mV | |
Temperature | -50 … +250 °C | ||
Sensor standardization | ORP calibration (zero adjustment) | ||
Permissible calibration range |
ΔmV (offset) |
-700 … +700 mV | |
Sensor standardization
Operating modes
Calimatic buffer sets
Permissible calibration range
|
pH calibration | ||
Calimatic | Calibration with automatic buffer recognition | ||
Manual | Manual calibration with entry of individual buffer values | ||
Data entry | Data entry of zero and slope | ||
Knick CaliMat | Ciba (94) | User defined | |
NIST technical | HACH | Mettler-Toledo | |
NIST standard | Hamilton | WTW techn. buffers | |
DIN 19267 | Reagecon | ||
Zero point | 6 ... 8 pH | ||
With ISFET: | –750 … +750 mV operating point (asymmetry) | ||
Slope | Approx. 74 … 104 % | ||
Calibration timer*)
Sensoface
|
Interval | 1 … 99 days, can be switched off | |
Provides information on the sensor condition | |||
Evaluation of | zero/slope, response, calibration interval |
If you cannot find what you want, you can entrust ISweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Smart Aqua Meter for pH, ORP or Conductivity and Temperature Meter
-
Loop-Powered, Isolated Toroidal Conductivity Transmitter
-
Menu Driven Loop-Powered Toroidal Conductivity Transmitter
-
Loop-Powered Contacting Conductivity Transmitter
-
Loop-Powered Dissolved Oxygen Transmitter
-
pH/mV Transmitter
-
Multi-parameter (COD / BOD / TOC) Water Quality Automatic Analyzer
-
Cabinet Mounted Turbidity / TSS / MLSS Analyzers
-
Cabinet Installed Chlorine Analyzer (Polarography)
-
On-line TRO Analyzer (DPD Spectrophotometry)